◆ General description:
This series control unit consists of rectification program control panel and operational chamber. The program control and the time setting adopt PC control; the rectified current is adopt the various voltage transformer branch to change the voltage in the silicon rectification strong & weak excitation way. It convenient for commissioning and test run, its working performance is reliable and steady.
Program control panel Operational panel

◆ Pattern selection & attention
When choosing series MC01 ore self-recovering separator, according to the principle the max cold state power consumption of the corollary separator should not be over the rated capacity of the equipment.
|
Model Data |
Input AC noltage (V) |
Output DC Voltage (V) |
Capacity (kw) |
External & installation dimension (mm) |
Weight (kg) |
|||||
|
W |
D |
H |
X |
Y |
||||||
|
Rectification Program Control panel |
GJK□-PC |
380 |
350/290/100/90 |
15/10.3/1.22/0.9 |
1020 |
600 |
2060 |
920 |
460 |
280 |
|
GJK□-PC |
20/13.5/1.63/1.32 |
|||||||||
|
GJK□-PC |
25/17.12/2.04/1.65 |
|||||||||
|
GJK□-PC |
35/24/2.85/2.31 |
1200 |
2260 |
1120 |
300 |
|||||
|
GJK□-PC |
45/30.5/3.67/2.97 |
350 |
||||||||
|
GJK□-PC |
65/44.6/5.3/4.29 |
360 |
||||||||
|
GJK□-PC |
100/68.5/8.1/6.61 |
380 |
||||||||
|
GJK□-PC |
120/82.3/9.79/7.93 |
400 |
||||||||
|
Operational chamber |
CX□-1/PC |
380 |
|
|
580 |
340 |
700 |
540 |
400 |
65 |
Note: 1. The 4 values on the capacity column means rated output capacity of equipment at different outputting voltage.
2. The rectification voltage transformer is installed outside when the equipment's max capacity exceeds 45KW.
Corollary metal detector and user signal connect handing over sketch
|
Model |
Hand-overt point signal |
Sets of metal detector |
note |
||
|
Iron detect |
Metal detect |
Iron detect |
Metal detect |
||
|
GJK1-□/PC |
1. ready for operation 2. main loop trouble 3. detector trouble 4. separator running 5. metal detecting 6. continuous metal detecting 7. continuous metal transferring belt stop interface |
1. ready for operation 2. main loop trouble 3. detector trouble 4. separator running 5. metal detecting 6. continuous metal detecting 7. continuous metal transferring belt stop interface |
1 set |
2set |
1. the required signal can be wired into the main control chamber per the customers site operating conditions 2. the operational panel has control buttons as well as signal display |
|
GJK21-□/PC |
2set |
4set |
|||
|
GJK22-□/PC |
|||||
Note: 1. Iron picking up in column of Interface signal refers to detecting among the magnetic materials and removing the iron pieces; " Metal Picking Up" refers to detecting the magnetic metal (such as iron pieces) as well as non-magnetic metal (such as high manganese steel), and the magnetic metal auto picked up by the iron separator, the non-magnetic metal can only be manually picked up when the material conveyer is conducted to stop.
2. The output signal interface is for passive contact. " Belt Stop" interface are of a pair of normal open passive contact and a pair of normal close passive contacts. The other interfaces in principal are a pair of normal open passive contacts.